Back to TEST features.

Open Specific Steady-State Devices>Steady Flow Combustion back

In an adiabatic combustion chamber, CH4 is burned at a rate of 1 kg/s with 1 kg/s of O2. Determine the temperature of the products at the exit. 

Solution: Step-by-step instructions as well as the TEST-Code can be found in the Tutorial>Daemons>Combustion>Practice page. An image of the Reaction panel  is reproduced from the Slide Show below.