Back to TEST features.

Open Specific Steady-State Devices>Rankine Cycle back

In a steam power plant operating on a reheat Rankine cycle, steam enters the HP turbine at 15 MPa and 620oC and is condensed in the condenser at a pressure of 15 kPa. If the moisture content in the turbine is not to exceed 10%, determine (a) the reheat pressure and (b) the thermal efficiency of the cycle.

What-If Scenario: How do the answers change if themoisture content in the turbine is not to exceed 15%? 

Solution: Step-by-step instructions as well as the TEST-Code can be found in the Tutorial>Daemons>OpenCycle>Practice page. An image of the Cycle Panel is reproduced from the Slide Show below.